There are three types of air leakage in the cyclone dust collector: the inlet and outlet connection flanges, the dust collector body and the dust discharge device. The causes of air leakage are as follows: 1) The air leakage at the connection flange is mainly that the bolts are not tightened and the thickness of the gasket is uneven. , the flange surface is not flat, etc. 1. Anti-cyclone dust collector to prevent air leakage and key parts wear, avoid dust clogging, otherwise it will seriously affect the dust removal effect. Stable operating parameters Cyclone dust collector operating parameters mainly include: dust collector inlet Air flow rate, temperature of the process gas and inlet mass concentration of the dust-containing gas.
Activated Carbon is a very small carbon particle with a large surface area, and there are even smaller holes in the carbon particle-capillary. This capillary has a strong adsorption capacity, because of the large surface area of the carbon particles, it can be in full contact with gas(impurities). When these gases(impurities) touch the capillary, they are adsorbed and act as purifiers. The study of the surface area of activated carbon is very important. The detection data of the specific surface area of activated carbon is only true and reliable by using the BET method. At present, there are many instruments in China that can only be detected by direct comparison methods. Now it is also in China. It was eliminated. At present, multi-point BET method is used for specific surface area testing at home and abroad. The specific surface area measurement standards formulated at home and abroad are based on BET test methods. See the Chinese National Standard(GB/T 19587-2004)-BET principle for the determination of the surface area of solid substances. The specific surface area detection is actually a more time-consuming task. Due to the different adsorption capabilities of samples, the testing of some samples may take a whole day. If the test process is not fully automated, the testers can not leave at all times. And to be highly focused, observe the dashboard, control the knob, and inadvertently lead to the failure of the test process, which will waste a lot of valuable time for the tester. The F-Sorb 2400 ratio surface area tester is an instrument that can truly achieve the BET method detection function(with a direct comparison method). The more important F-Sorb 2400 ratio surface area tester is the only fully automated and intelligent surface area detection device in China so far., Its test results are highly consistent with international standards and have good stability. At the same time, it reduces human error and improves the accuracy of test results.
Adsorption Activated Carbon,Dry Activated Carbon Desiccant,Graphite Particles Carbon Agent,Capacit Granular Activated Carbon
NINGXIA SINOTOPSKY INTERNATIONAL TRADING CO.,LTD. , https://www.nxsinotopsky.com