Swing gate common faults and treatment methods

What are the parts of the swing gate?
The swing gate is also called the swing door. Its structure consists of: the swing gate is composed of the chassis, movement, swing arm, control system, infrared sensor, and control equipment.

Second, what kind of swing gate?

1. The type of the swing gate is divided according to the shape: box-type swing gate and cylindrical swing gate. The cylindrical pendulum brake is further divided into an integrated cylindrical swing gate and a split cylindrical swing gate.

The advantage of the box-type swing gate is that the box body is large in size, and it is easy to install the swipe pipe system and other equipment into the gate;

Cylindrical pendulum sluice is relatively small in size, small in size, beautiful in appearance, application is not easily affected by the site, and is accepted by most users.

2. According to the mode of traffic, it can be divided into: electric swing gate and manual swing gate. Electric swing gate generally needs to be controlled by external control. The conventional application is controlled by buttons, IC/ID credit card system, fingerprint identification system and other devices. , With its own infrared sensors and other automatic detection devices can achieve rapid passage of personnel, manual swing gate is generally used in shopping malls, customs, bookstores and other places only need to use a one-way control. At the same time, it can evolve into a manual turning gate machine.

Third, what are the features of standard products?

1. Through the built-in small button on the main control board, the operating status of the device can be programmed online;

2. With fault self-test and alarm prompts, user-friendly maintenance and use;

3. Anti-collision function, when the arm is blocked during the reset process, the motor will automatically stop working within the specified time, and the force is very small;

4. Anti-knock function, the swing arm is automatically locked when no open signal is received;

5. Swing arm synchronously adjustable (for double pendulum situation);

6. With automatic reset function, the system will automatically cancel the user's permission to pass this time when the gate is not in use within the specified time.

7. Delay automatic reset, the standard is 5 seconds after the automatic reset;

8. Can be connected with a variety of card reading equipment, receiving relay switch signal work;

9. Two-way pendulum, single, two-way control personnel in and out;

10. Remote control and management can be realized directly through the management computer;

11. Normally powered off to meet fire management requirements;

Fourth, what are the common faults? Swing door common faults and handling methods are as follows:

1. After the card is swiped, the door is not opened, there is no response, or it is not turned on automatically after the power is turned off. Check again to see if the signal cable is dropped. Check whether the signal indicator on the main board is open. signal.

2. After swiping, the gate opens but the gate does not close. This situation is usually not good for the middle anti-clip infrared. Before fixing the chassis, it must be determined that the infrared pair is good enough to open and close the door normally. If there is no good infrared, after power on, it will alarm. After swiping, please use the direction arrow to exercise.

3. After swiping and swiping, there is one open and one not open. Check again if the sync line is connected. After the connection is guaranteed, if the motherboard that does not open has received an open signal, if not, check whether the wiring is dropped or if the plug on the motherboard is plugged in.

4. The swing gate has an automatic opening function after power off. If it does not turn on after power off, the reason is that the voltage of the backup battery (battery) inside is not enough, and the voltage of the multimeter can be more than 10V.

5. The working status of the direction indication is that the green arrow points left, right, or red cross. If the direction indicates no response, or the direction of the indication is incorrect. You can switch to another test and try it with a good one. Check the wiring again.

5. What problems should be paid attention to when swinging the door? The following points are the main points of attention when using the swinging door:

1. The equipment should be properly managed when it is not working, and it is forbidden to knock or shake the equipment.

2.Before the swing gate is put into use, it must be debugged through function, and it can be put into use after normal debugging;

3. When pedestrians pass the passage, do not stay in the middle of the passage for a long time;

4. When a pedestrian reads a cartoon line, the sign of the direction indicator does not turn green and it is forbidden to enter the channel;

5. When passing through the gateway, do not be crowded and keep a certain distance between people.

6. It is strictly forbidden to read the card and quickly pass through the gateway;

7. When the swing door is closed, it is forbidden to forcefully push or pull the gate;

8. It is forbidden to station people in the channel when power is applied to the swing gate;

9. It is advisable to mark the passage notice of the machine at a conspicuous place in the swinging door work and guide the passers through the gate passage safely and orderly.