Inappropriate pesticide

In agricultural production, if the failed pesticides are misused, there is no control effect, and the crops may be damaged and the production may be reduced or even lost. The following describes the identification methods of several failed pesticides to readers.

Dry powders Such pesticides, if they are in a damp state, can form a wet mass when held by hands, and are semi-failed pesticides; if they form a soft block, they all fail. Normal dry powder pesticides should be free of moisture and agglomeration.

Wettable powders Take a small amount of pesticide and pour it into a container. Add a proper amount of water to make it into a paste. Then add a small amount of water and mix well. After standing, observe. In the case of an undeteriorated pesticide, the suspension property is good, the precipitation rate of the powder particles is slow, and the precipitate is particularly small. On the contrary, pesticides with different degrees of failure or deterioration should be used with caution.

Emulsions When distinguishing such pesticides, the flask can be shaken vigorously and allowed to stand for about 1 hour before observation. If stratification occurs, the pesticide has expired. In addition, the medicine bottle can be placed in warm water, and it is observed after the heat absorption. If it is an undeteriorated pesticide, the precipitate in the bottle will slowly dissolve or even disappear completely; otherwise, it is a failed pesticide.
【Comment】 【Print this article】 【Close this page】 【Large, medium and small】

Tip Combs

These tip combs are for use with the Pharma KingFisher Flex 96 Deep-Well Head Magnetic Particle Processor or MagMAX Express-96 Deep-Well Magnetic Particle Processor in combination with PrepSEQ ResDNA kits and ProteinSEQ kits.
Optimize performance using KingFisher Flex System consumables designed specifically for use with these instruments. KingFisher Flex disposable plastics (tip combs and microplates) are made of polypropylene and are ideal for magnetic particle processing because of their low binding affinity for biomolecules. Their special design enables excellent recovery of magnetic beads.
The tip combs are made of PP material, they can be used with 2.2ml square well V bottom and 0.5ml elution plates for the system KINGFISHER FLEX. The tip combs could suffer centrifuge 3000-4000 and don't change the original shape. The products are suitable for the standard ANSI and multi-channel Pipette Tips machnie and automatic equipment. We could accept OEM/ODM.

For use with Viral RNA extraction, DNA extraction, RNA/DNA quantification, immunopreciptitations and many more KingFisherâ„¢ applications
good chemical and physical resistance: e.g. phenols, chloroform, DMSO and temperatures as low as -80°C/-112°F

tip comb

Tip Comb,Tip Comb Plate,Kingfisher Tip Comb,Tip Comb Kingfisher,Magnetic Tip Comb,8-Strip Tip Comb

Yong Yue Medical Technology(Kunshan) Co.,Ltd , https://www.yongyuepcrtube.com