Anti-static floor to solve the problem of static electricity on the computer

1. For the safety of computer equipment, for schools or other qualified entities, when using computers collectively, anti-static flooring must be laid in computer classrooms. Never use ordinary chemical fiber carpets.

2. The power supply used by computer equipment must be well grounded. It is recommended to use a three-hole power outlet. Of course, the power cord must also be three-pin. Some friends use a wire to connect the chassis with the ground or the water pipe. This method does not achieve good results. If there is no grounding device, when we need to touch the card with our hands, we must touch the water pipe or wet ground with our hands to discharge the static electricity carried by ourselves and avoid the personal discharge to the card when we touch the card. Causes damage to the board. Especially in winter, when it is dry and cold, most of the clothes we wear are wool chemical fiber products, which are most likely to generate static electricity.



Gas Industry Mass Flow Meter

Sealand is a trustworthy manufacturer of Gas Mass Flow Meter, Gas Mass Flowmeter, Gas Flow Meter, Gas Flowmeter, Gas Meter, ATEX, IECEx & CE approved.



The installation is as follows.

1. Installation Steps
a) Choose correct installation site, taking installation area, pipeline, transmitter location &

valve location into consideration;
b) Install the meter according to direction mark on sensor; c) Install the sensor & transmitter on pipeline;
d) Connect transmitter & sensor with 9-pin cable;
e) Start.


2. Site selection

a) Sensor stays away from mechanical vibration source, for example, pump. Use flexible pipe to connect meter with pipeline if inevitable. The housing of meter must be standalone, out of touch with any other device. There must be 3 times the size of sensor between 2 sensors if there are many flow meters on the same pipeline, to avoid resonance.

b) Do not install sensor on pipeline that easily expands with hot and contracts with cold, especially near expansion joint, which leads to a worse stability.

c) Sensor stays away from industrial electromagnetic field, such as large generator and transformer, better 5m at least. Such device influences the performance of drive coil and pickoffs. Make sure magnetic field intensity less than 400A/m.

d) Sensor shall be installed on lower pipeline, to be easily full of fluid.
e) Make sure Ex-mark meet application requirements if in hazardous area.

f) Build a sunshade if the meter is under direct solar radiation. g) Keep the meter from corrosive liquid.